Sign In | Join Free | My burrillandco.com
Home > VPSA Oxygen Generator >

VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use

Henan Gnee New Materials Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers
     
    Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers
    • Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers
    • Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers
    • Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers
    • Buy cheap VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from wholesalers

    VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use

    Ask Lasest Price
    Brand Name : GNEE
    Certification : SGS
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Delivery Time : Transit time: Est. 17-24 days
    • Product Details
    • Company Profile

    VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use

    VPSA Oxygen Generator (Vacuum Pressure Swing Adsorption Oxygen Generator) realizes the separation of oxygen and nitrogen in the cyclic process of low-pressure adsorption and vacuum desorption through the coordinated work of components such as adsorption towers, vacuum pumps and blowers. Taking air as raw material and relying on the selective adsorption function of molecular sieves, it produces high-purity oxygen. It has the characteristics of low energy consumption, long service life and low operation and maintenance costs, and is the preferred solution for large-scale oxygen supply scenarios.

    Product Parameters

    Model

    Oxygen storage tank

    External dimensions

    (m)

    Total weight

    Power
    KW

    VPSA-1

    OG20

    6.1×1.5×2.4

    1600

    5.5

    VPSA-2

    OG20

    6.1×1.5×2.4

    1800

    5.5

    VPSA-3

    OG20

    6.2×1.5×2.4

    2100

    5.5

    VPSA-4

    OG30

    6.3×1.7×26

    2300

    7.7

    VPSA-5

    OG30

    6.4×1.7×2.6

    2500

    7.7

    VPSA-6

    OG50

    6.5×1.7×3.2

    3000

    11.7

    VPSA-7

    OG50

    6.7×1.7×3.2

    3500

    11.9

    VPSA-8

    OG50

    6.7×1.7×3.2

    3700

    11.9

    VPSA-9

    OG50

    10.5×1.75×3.2

    3800

    16

    VPSA-10

    OG50

    10.5×1.75×3.2

    3850

    16

    VPSA-11

    OG50

    10.5×1.75×3.2

    3900

    16

    VPSA-12

    QGF0

    10.5×1.75×3.2

    3950

    16.5

    VPSA-13

    CG50

    11×1.75×3.2

    4000

    20

    VPSA-14

    0G50

    11×1.75×3.2

    4100

    20

    VPSA-15

    OG50

    11×1.75×3.2

    4150

    23.5

    VPSA-16

    OG50

    11.5×1.75×3.2

    4200

    23.5

    VPSA-17

    OG50

    11.5×1.75×3.2

    4300

    23.5

    VPSA-18

    OG50

    12×1.75×3.2

    4500

    31.5

    VPSA-19

    OG50

    11.5×1.75×3.2

    4600

    31.5

    VPSA-20

    OG50

    11.5×1.75×3.2

    4650

    31.5

    VPSA-21

    OG50

    11.5×1.75×3.2

    4900

    31.5

    VPSA-22

    OG50

    12.5x1.75x3.2

    5000

    31.5

    VPSA-23

    OG60

    12.8x1.75x3.25

    5200

    31.5

    VPSA-24

    OG60

    12.9x1.75x3.25

    5300

    32.5

    VPSA-25

    OG60

    12.9x1.75x3.25

    5350

    32.5

    VPSA-26

    OG60

    13x1.75x3.25

    5400

    32.5

    VPSA-27

    OG60

    13.8x1.75x3.25

    5450

    39.5

    VPSA-28

    OG60

    13.8x1.75x3.25

    5500

    39.5

    VPSA-29

    OG60

    13.85.x19x3.25

    5550

    39.7

    VPSA-30

    OG60

    14.5x1.9x3.25

    5800

    39.7

    VPSA-31

    OG60

    14.5x1.9x3.25

    5850

    39.7

    VPSA-32

    OG60

    14.5x1.9x3.25

    5800

    39.7

    VPSA-33

    OG60

    15x1.9x3.25

    5950

    47.7

    VPSA-34

    0060

    15x1.9x3.25

    6000

    47.7

    VPSA-35

    OG60

    15x1.9x3.25

    6050

    47.7

    VPSA-36

    OG60

    15.5x1.9x3.25

    6300

    48

    VPSA-37

    OG60

    15.5x1.9x3.25

    6350

    48

    VPSA-38

    OG60

    15.5x1.9x3.25

    6400

    48

    VPSA-39

    OG60

    15.5x1.9x3.25

    6450

    48

    VPSA-40

    OG60

    15.5x1.9x3.25

    6500

    58

    VPSA-41

    OG100

    15.5x2.3x3.35

    7700

    58

    VPSA-42

    OG100

    15.5x2.3x3.35

    7750

    58

    VPSA-43

    OG100

    15.5x2.3x3.35

    7800

    58

    VPSA-44

    OG100

    15.5x2.3x3.35

    7850

    58

    VPSA-45

    OG100

    15.5x2.3x3.35

    7850

    58

    VPSA-46

    OG100

    15.5x2.3x3.35

    7900

    59

    VPSA-47

    OG100

    15.5x2.3x3.35

    7900

    59

    VPSA-48

    OG100

    15.5x2.3x3.35

    8050

    59

    VPSA-49

    OG100

    15.5x2.3x3.35

    8200

    79

    VPSA-50

    OG100

    15.5x2.3x3.35

    8250

    79


    VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use





















    VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use























    VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use


    Transportation Planning and Packaging Requirements

    Transporting VPSA Oxygen Generators requires careful planning to protect precision components, as the equipment consists of fragile parts such as adsorption towers, sensors, and control panels. The first step is to select the appropriate transportation method based on the equipment size and distance: for small units (≤50Nm³/h), road transportation via enclosed van trucks is preferred; for large modular systems (≥1000Nm³/h) or long-distance international transportation, sea freight in containers is more cost-effective.


    Packaging is critical to prevent damage during transit. For complete units, the equipment is fixed on a steel base frame (with a load-bearing capacity 1.5 times the equipment weight) and wrapped with moisture-proof film and shock-absorbing foam. The adsorption tower, which is the heaviest component (weighing 500-5000kg depending on capacity), is secured with steel brackets at the top and bottom to prevent tilting or collision.


    For split-module transportation (common for large systems), each module is packaged separately: the molecular sieve module is sealed with nitrogen (pressure 0.05MPa) to prevent moisture absorption; the control system is placed in a waterproof and shockproof cabinet with foam padding for sensors and touchscreens; the blower and vacuum pump are wrapped with oil-proof film to avoid leakage of lubricating oil. All packages are labeled with "Fragile", "Keep Upright", "No Stacking" and other signs, and the center of gravity is marked to guide handlers.

    Transportation Process Control and On-Site Inspection


    During road transportation, the speed of the truck should not exceed 60km/h on highways and 30km/h on rural roads to minimize vibration. Avoid sudden acceleration, braking, or sharp turns, as these can cause displacement of internal components. For long-distance transportation (≥500km), stop every 200km to inspect the packaging—check for loose brackets, damaged film, or oil leakage, and make timely adjustments.


    For sea freight, the container should be equipped with moisture-proof agents (1-2kg per cubic meter) to prevent corrosion of metal components due to high humidity in the marine environment. The equipment should be fixed to the container floor with bolts to withstand the rolling and pitching of the ship. Before shipment, conduct a pre-transportation inspection: test the tightness of the adsorption tower, calibrate the sensors, and record the initial status of the equipment.


    Upon arrival at the destination, conduct a comprehensive on-site inspection before unloading. Check the packaging for damage, the steel frame for deformation, and the seals of the molecular sieve module for air leakage. Use a crane with a lifting capacity 1.2 times the equipment weight for unloading, and avoid lifting the equipment by the pipelines or control panel. After unloading, place the equipment in the pre-prepared installation site and let it stand for 2-4 hours to allow the internal components to stabilize (especially the lubricating oil in the motor) before installation.


    In addition to VPSA Oxygen Generators, we also produce PSA Oxygen Generators, storage tanks, heat exchangers and other products. If you are interested in VPSA Oxygen Systems or other products, please feel free to send an email to info@gneeheatex.com. We will be very happy to serve you.

    Quality VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Henan Gnee New Materials Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)